The NIBE BA-SVM is a compact indoor module suitable for air to water split systems. The outdoor module AMS is connected with refrigerant pipes to the NIBE BA-SVM. The NIBE BA-SVM provides optimum savings since the heat pump automatically adjusts to the property’s output requirements all year round. The NIBE BA-SVM works down to an outdoor temperature of –20°C and supplies up to 58°C in supply line temperature. The effective cooling function allows the heat pump to deliver a comfortable indoor climate even at high outdoor temperatures.
INTELLIGENT TECHNOLOGY
Compact heat pump that adapts to the needs of the house.
POWERFUL
High capacity even down to -20°C and effective cooling function
EASY
Simple and easily placed indoor module.
A SIMPLER LIFE
Part of your smart home - Control your comfort online with NIBE Uplink.
Refrigerant pipe kit 12m
Provides the heat pump together with SMO 10 to prioritise hot water charging on systems with floating condensing. This also requires a hot water accumulator, for ex. NIBE VPA. Hot water control for max.electric charge output: 18 kW
Makes hot water priority possible at large heat pump outputs. (charging power between 15 and 40 kW), together with an SMO 10 and F1330-40. This also requires a hot water accumulator, for example, NIBE VPA.
The NIBE POOL 40 accessory provides a complete, ready-engineered solution for integrating pool heating into a NIBE ground source heat pump system. Using its dedicated AXC module, motorised 3-way valve and paired pool sensors, the unit automatically diverts heating medium flow through a pool heat exchanger whenever pool heating is enabled. The accessory controls both the pool circulation pump and any required external heating medium pump, ensuring correct flow and accurate temperature readings throughout the charge cycle. Built-in sensor validation ensures pool heating only activates under safe conditions, providing dependable operation and seamless interaction with the wider heat pump system.
The NIBE KVR range provides installers with a simple, reliable and freeze protected way to manage condensate drainage from NIBE air source heat pumps. KVR 10 is for the F2050-6 and F2050-10 and is available in multiple lengths, indicated by the suffix; for example, KVR 10-10 = 1 m, KVR 10-30 = 3 m, and KVR 10-60 = 6 m. All variants combine insulated pipework with a thermostat-controlled heating cable that automatically prevents ice formation, ensuring safe drainage even in sub-zero conditions and protecting the heat pump from backflow, frost damage or condensate pooling.
Condensation water pipes for F2040. Different lengths, 1, 3 or 6 m.
The NIBE KVR range provides installers with a simple, reliable and freeze protected way to manage condensate drainage from NIBE air source heat pumps. KVR 10 is for the F2050-6 and F2050-10 and is available in multiple lengths, indicated by the suffix; for example, KVR 10-10 = 1 m, KVR 10-30 = 3 m, and KVR 10-60 = 6 m. All variants combine insulated pipework with a thermostat-controlled heating cable that automatically prevents ice formation, ensuring safe drainage even in sub-zero conditions and protecting the heat pump from backflow, frost damage or condensate pooling.
The NIBE EMK 300 energy metering accessories provides installers with a reliable way to monitor the actual energy delivered by a NIBE heating system, measuring both flow and temperature difference within the charge circuit to determine output for heating, domestic hot water or additional climate zones. The kit includes a precision flow meter, pre-terminated communication cable and the necessary pipework and unions for straightforward installation. The EMK 300 is suitable for lower-flow systems.
Room sensor used to obtain a more even indoor temperature. RTS 40 has up to three functions: Show current room temperature in the heat pump's display. Option of changing the room temperature in °C. Makes it possible to change/stabilise the room temperature.
A NIBE heat pump can be controlled and monitored by external Modbus equipped equipment.
With RMU 40 you can control and monitor your Nibe heat pump from another room in the house.
Auxiliary relay HR 10 is a connection box housing a contactor and a rotary selector switch. It is used to control external 1 to 3-phase loads such as oil burners, immersion heaters and pumps.
HTS 40 is an accessory that records humidity and temperature.
Communication module that translates Modbus RTU, from a solar inverter, to Modbus TCP/IP, for the heat pump to control the solar inverter
ECS 40 is used when heat pump is installed in houses with up to four different climate systems that require different flow line temperatures, for example, in cases where the house has both a radiator system and an under floor heating system.
The NIBE ECS 41 kit allows installers to add one or more additional heating circuits to a NIBE heat pump installation where different supply temperatures are required, such as radiator and underfloor heating combinations. Each kit includes a dedicated AXC accessory module, shunt valve, shunt motor, circulation pump and temperature sensor, enabling the new zone to run as a fully controlled climate system with independent flow temperature, heating curve and pump operation. The ECS 41 is sized for larger UFH areas above 80 m².
Height (mm)
1610
Width (mm)
600
Depth (mm)
610
Net weight (kg)
163
Product efficiency class room heating, 35 °C
A+++
Product efficiency class room heating, 55 °C
A++
System efficiency class room heating, 55 °C
A++
System efficiency class room heating, 35 °C
A+++
Volume water heater (l)
180