NIBE™ COMPACT

The water heater consists of a stainless steel vessel, (grade EN 1.4521). The water tank is insulated with EPS (Environmentally friendly cellular plastic), which provides a good heat insulation. The outer shell is made from powder coated sheet steel and the rear panel is made from galvanised sheet steel. A complete set of valves, consisting of a mixer valve, nonreturn valve, safety/drain valve and shut-off valve, are factory fitted.

The base of the unit is generously sized to permit concealed piping connections. Piping can be brought up from beneath or down from above (through recesses in the back panel). There is sufficient space in the base to allow connection of a distribution manifold.

The lower section of the side plates on NIBE COMPACT can be removed during installation. This facilitates access from the sides.

The water heater is equipped with a terminal block for connecting the supply power cable. All models of NIBE COMPACT are equipped with a circuit breaker.

The water heater can be connected to 400 VAC two-phase 3 kW. The water heater can also be connected to 230 VAC singlephase if required, but then the power output is limited to 1.0 kW. (6 kW 400 VAC three-phase can be specially ordered.)

The flanged, stainless steel (Alloy 254 SMO) immersion heater in a Ø 80 mm connection opening allows for simple dismantling, internal inspection and cleaning of the vessel. Adjustable thermostatic control to 80°C.

Image: Water heaters/Product range/NIBE™ COMPACT
100 150 200 300
Corrosion resistant lining material Copper Stainless steel Enamel, Copper,
Stainless steel
Enamel, Copper,
Stainless steel
Heat content 80 °C 8.1 kW 11.8 kW 15.1 kW 22.4 kW
Heating-up time to 45°C at 1.0/3.0 kW 4.0/1.5 hours 6.0/2.0 hours 8.0/2.5 hours 11.5/4.0 hours
Heating-up time to 80°C at 1.0/3.0 kW 8.0/3.0 hours 12.0/4.0 hours 15.5/5.0 hours 22.5/7.5 hours
Volume 90 litres 145 litres 185 litres 275 litres
Net weight (E/Cu/R) 62 kg 56 kg 91/95/67 kg 117/122/87 kg
Height 820 mm 1120 mm 1310 mm 1710 mm
Widht 600 mm 600 mm 600 mm 600 mm
Depth 615 mm 615 mm 615 mm 615 mm
Power 1/3 kW 1/3 kW 1/3 kW 1/3 kW
Fuses required at 1.0/3.0 kW 6/10 A 6/10 A 6/10 A 6/10 A
Voltage 400 VAC
2-phase
or 230 VAC
400 VAC
2-phase
or 230 VAC
400 VAC
2-phase
or 230 VAC
400 VAC
2-phase
or 230 VAC
Enclosure class IP24 IP24 IP24 IP24
Anode length (only Compact Enamel) - - 435 mm 435 mm