The NIBE RCU 11 can receive incoming SMS commands and send back a reply. The table below shows the available commands. If an incorrect message is sent to the NIBE RCU 11, it will reply with a list of the available commands.
For the NIBE RCU 11 to send a reply to an incoming SMS, the number of the telephone from which the SMS command was sent must have been registered to a user, or that the number check for incoming SMS enquiries has been switched off.
Telephone number: 070-5103901
Send message: ?status
SMS commands for interrogating the heat pump:
NIBE FIGHTER 360P
Send SMS message: ?STATUS
| FIGHTER360P |
On/Off |
Heat pump status (contact between RCU and heat pump) |
| S-alarm: |
On/Off |
Common alarm |
| Out: |
nn,n |
Outside temperature |
| HW: |
nn,n |
Hot water temperature |
| H-out: |
nn,n |
Supply temperature |
| H-ret: |
nn,n |
Return temperature |
| Comp: |
On/Off |
Compressor data |
| Imm: |
On/Off |
Immersion heater is operational. |
| Mode: |
W / SA / S / A / EB |
Operating mode (Winter, Spring / Autumn, Summar, Auto, Electric Boiler) |
| XHW: |
0 / 3 / 6 / 12 / 24 |
Extra hot water function |
| Vent: |
0 / 1 / N / 2 |
Fan speed (Off / Speed 1 / Normal / Speed 2) |
| DI: |
1 / 2 / 12 |
RCU 11 digital inputs |
Send SMS message: ?STATUS2
| Vent |
nn,n |
Extract air temperature |
| Exh: |
nn,n |
Exhaust air temperature |
| Eva: |
nn,n |
Evaporator temperature |
| CPR: |
nn,n |
Compressor sensor temperature |
| IMM: |
nn,n |
Electic element sensor temperature |
| REG1: |
-10 - +10 |
Heating curve offset via RCU 11 |
| H-out2: |
nn,n |
Heating medium Flow line 2 |
| H-ret2: |
nn,n |
Heating medium Return line 2 |
| REG2: |
-10 - +10 |
Heating curve offset 2 via RCU 11 |
Send SMS message: ?ALARM
| HP |
On/Off |
High pressure |
| LP |
On/Off |
Low pressure |
| Filter |
On/Off |
Filter |
| Sensors |
On/Off |
Sensors |
| Therm.Co |
On/Off |
Temperature limiter |
NIBE FIGHTER 1140/1240
| FIGHTER |
On/Off |
Heat pump status (contact between RCU and heat pump) |
| S-larm |
On/Off |
Common alarm |
| Out: |
nn,n |
Outside temperature |
| HW: |
nn,n |
Hot water temperature |
| S: |
nn,n |
Supply temperature |
| Return: |
nn,n |
Return temperature |
| C.F.: |
nn,n |
Calculated flow temperature |
| DM: |
nn,n |
Current degree minutes |
| Br.i: |
nn,n |
Brine in temperature |
| Br.o: |
nn,n |
Brine out temperature |
| HW |
On/Off |
Hot water production activated |
| Mode: |
W / SA / S / A / Add. heat |
Operating mode (Winter / Spring-Autumn / Summer / Auto Additional Only) |
| XHW: |
0 / 3 / 6 / 12 / 24 |
Extra hot water function |
| Co: |
On/Off |
Compressor is operational |
| A.heat: |
On/Off |
Shows whether any additions are activated |
| DI: |
0 / 1 / 2 / 12 |
RCU 11 digital inputs |
| REG1: |
-10 - +10 |
Heating curve offset via RCU 11 |
| REG2: |
-10 - +10 |
Heating curve offset 2 via RCU 11 |
NIBE FIGHTER 1330
|
Send SMS message: ?STATUS |
| Fighter 1320 |
On/Off |
Heat pump status (contact between RCU and heat pump) |
| S-alarm |
On/Off |
Common alarm |
| Out: |
nn,n |
Outside temperature |
| HW: |
nn,n |
Hot water temperature |
| S: |
nn,n |
Supply temperature |
| System: |
M / S1 / S2 ...../ S8 |
Shows the units connected |
| C.F.: |
nn,n |
Calculated flow |
| DM: |
nn,n |
Current degree minutes |
| Mode: |
W / SA / S / A / Add.heat |
Operating mode (Winter / Spring-Autumn / Summer / Auto / Additional Only) |
| XHV: |
0 / 3 / 6 / 12 / 24 |
Extra hot water function |
| A.heat: |
On/Off |
Shows whether any additions are activated |
| DI: |
1 / 2 / 12 |
RCU 11 digital inputs |
| REG1: |
-10 - +10 |
Heating curve offset via RCU 11 |
| REG2: |
-10 - +10 |
Heating curve offset 2 via RCU 11 |
|
Send SMS message: ?STATUS M/S1-S8 |
| Comp A: |
Heat / HW / ... |
Shows the current status of compressor A (operating type or alarm) |
| Comp B: |
Heat / HW / ... |
Shows the current status of compressor B (operating type or alarm) |
| Flow: |
nn,n / nn,n |
Heat medium temperature supply to compressor A/ B |
| R: |
nn,n / nn,n |
Heat medium temperature return from compressor A/ B |
| Br.i: |
nn,n / nn,n |
Cooling medium temperature input to compressor A/ B |
| Br.o: |
nn,n / nn,n |
Cooling medium temperature exit from compressor A/ B |