NIBE RCU 11

The NIBE RCU 11 enables operations on a NIBE heat pump (FIGHTER 360P, 1140, 1150, 1240, 1250, 1330) to be controlled and monitored using a computer connected to a local network or via the Internet. The integrated GSM module also enables control and monitoring by sending text messages from a mobile phone.

Test demo

  • Login and look at the interface of a NIBE FIGHTER 360P online.
  • Login and look at the interface of a NIBE FIGHTER 1240 online.
  • Login and look at the interface of a NIBE FIGHTER 1330 online.

 

User ID: nibedemo
Password: nibedemo

Messages via SMS

See Technical Data.

Image: Products/Accessories/NIBE RCU 11

With the computer or the moblie phone you can for example operate:

  • room temperature
  • fan speed
  • operating mode
  • activate extra hot water

The following heat pumps can be operated with the communication module:

System requirements

  • Pentium 133 MHz
  • 5 MB free hard disk space
  • Windows 95/98/ME/NT/2000/XP
  • Network card (Ethernet)

 

If a different operating system than Windows is used the configuration software can not be used. Then connect to the RCU’s preset IP address in the web browser and use the web interface to change the network settings. See section “Starting” – “Logging

Note that all configuration of the unit requires that a computer with support for ”JAVA-applets” is connected, even if only text messaging is going to be used. Download on java.com.

You need an internet connection to be able so communicate via Internet.

The modem requires a 3.3-V SIM card (if you want to communicate with the heat pump via SMS).

Test demo

  • Login and look at the interface of a NIBE FIGHTER 360P online.
  • Login and look at the interface of a NIBE FIGHTER 1240 online.
  • Login and look at the interface of a NIBE FIGHTER 1330 online.

 

User ID: nibedemo
Password: nibedemo  

Image: Products/Accessories/NIBE RCU 11

Test demo

  • Login and look at the interface of a NIBE FIGHTER 360P online.
  • Login and look at the interface of a NIBE FIGHTER 1240 online.
  • Login and look at the interface of a NIBE FIGHTER 1330 online.

 

User ID: nibedemo
Password: nibedemo  

Messages via SMS

The NIBE RCU 11 can receive incoming SMS commands and send back a reply. The table below shows the available commands. If an incorrect message is sent to the NIBE RCU 11, it will reply with a list of the available commands.

For the NIBE RCU 11 to send a reply to an incoming SMS, the number of the telephone from which the SMS command was sent must have been registered to a user, or that the number check for incoming SMS enquiries has been switched off.

Telephone number: 070-5103901
Send message: ?status

SMS commands for interrogating the heat pump:

NIBE FIGHTER 360P

Send SMS message: ?STATUS

Answer Value Description
FIGHTER360P On/Off Heat pump status (contact between RCU and heat pump)
S-alarm: On/Off Common alarm
Out: nn,n Outside temperature
HW: nn,n Hot water temperature
H-out: nn,n Supply temperature
H-ret: nn,n Return temperature
Comp: On/Off Compressor data
Imm: On/Off Immersion heater is operational.
Mode: W / SA / S / A / EB Operating mode (Winter, Spring / Autumn, Summar, Auto, Electric Boiler)
XHW: 0 / 3 / 6 / 12 / 24 Extra hot water function
Vent: 0 / 1 / N / 2 Fan speed (Off / Speed 1 / Normal / Speed 2)
DI: 1 / 2 / 12 RCU 11 digital inputs

 

Send SMS message: ?STATUS2

Answer Value Description
Vent nn,n Extract air temperature
Exh: nn,n Exhaust air temperature
Eva: nn,n Evaporator temperature
CPR: nn,n Compressor sensor temperature
IMM: nn,n Electic element sensor temperature
REG1: -10 - +10 Heating curve offset via RCU 11
H-out2: nn,n Heating medium Flow line 2
H-ret2: nn,n Heating medium Return line 2
REG2: -10 - +10 Heating curve offset 2 via RCU 11

 

Send SMS message: ?ALARM

Answer Value Description
HP On/Off High pressure
LP On/Off Low pressure
Filter On/Off Filter
Sensors On/Off Sensors
Therm.Co On/Off Temperature limiter

NIBE FIGHTER 1140/1240

Parameter Value Description
FIGHTER On/Off Heat pump status (contact between RCU and heat pump)
S-larm On/Off Common alarm
Out: nn,n Outside temperature
HW: nn,n Hot water temperature
S: nn,n Supply temperature
Return: nn,n Return temperature
C.F.: nn,n Calculated flow temperature
DM: nn,n Current degree minutes
Br.i: nn,n Brine in temperature
Br.o: nn,n Brine out temperature
HW On/Off Hot water production activated
Mode: W / SA / S / A / Add.
heat
Operating mode (Winter / Spring-Autumn / Summer / Auto
Additional Only)
XHW: 0 / 3 / 6 / 12 / 24 Extra hot water function
Co: On/Off Compressor is operational
A.heat: On/Off Shows whether any additions are activated
DI: 0 / 1 / 2 / 12 RCU 11 digital inputs
REG1: -10 - +10 Heating curve offset via RCU 11
REG2: -10 - +10 Heating curve offset 2 via RCU 11

NIBE FIGHTER 1330

Send SMS message: ?STATUS

Parameter Value Description
Fighter 1320 On/Off Heat pump status (contact between RCU and heat pump)
S-alarm On/Off Common alarm
Out: nn,n Outside temperature
HW: nn,n Hot water temperature
S: nn,n Supply temperature
System: M / S1 / S2 ...../ S8 Shows the units connected
C.F.: nn,n Calculated flow
DM: nn,n Current degree minutes
Mode: W / SA / S / A /
Add.heat
Operating mode (Winter / Spring-Autumn / Summer /
Auto / Additional Only)
XHV: 0 / 3 / 6 / 12 / 24 Extra hot water function
A.heat: On/Off Shows whether any additions are activated
DI: 1 / 2 / 12 RCU 11 digital inputs
REG1: -10 - +10 Heating curve offset via RCU 11
REG2: -10 - +10 Heating curve offset 2 via RCU 11

Send SMS message: ?STATUS M/S1-S8

Parameter Value Description
Comp A: Heat / HW / ... Shows the current status of compressor A (operating type
or alarm)
Comp B: Heat / HW / ... Shows the current status of compressor B (operating type
or alarm)
Flow: nn,n / nn,n Heat medium temperature supply to compressor A/ B
R: nn,n / nn,n Heat medium temperature return from compressor A/ B
Br.i: nn,n / nn,n Cooling medium temperature input to compressor A/ B
Br.o: nn,n / nn,n Cooling medium temperature exit from compressor A/ B