NIBE™ F1145

NIBE F1145 is a ground source heat pump for heating single and multi-family houses and industrial buildings. The latest generation NIBE ground source heat pumps are not only more efficient than previous models, but have also been designed for user friendly operation.

It’s easier than ever to get the full benefits of this clean, cost-effective technology. Install a NIBE heat pump and you can reduce your energy cost by up to 80% - which means a dramatic reduction in both heating bills and CO2 emissions.

A control unit helps you maintain a comfortable indoor climate, both cost-effectively and safely. Clear information about status, operation time and all temperatures in the heat pump are shown on the large and easy to- read display.

Watch the movie about NIBEs new generation of heat pumps >>

Try out the new display.
www.nibe.eu/news


Read our new brochure

Click on the brochure.

Image: Ground source heat pumps/Product range/NIBE™ F1145

User friendly

A unique, intuitive control panel lets you set a comfortable indoor climate and schedule your heating system to suit the demands of the household.

Quiet operation

Noise levels are so low, you will hardly notice it’s there!

Adaptable design

A modular design means you can add accessories such as a ventilation unit or accumulator tank without ruining the system’s neat, streamlined appearance.

Add accessories, such as extra hot water heater, ventilation recovery, underfloor heating, pool and/or solar panels and other heating systems.


NIBE F1145 with accumulator tank NIBE VPB 200.

 

Image: Ground source heat pumps/Product range/NIBE™ F1145

1 x 230 V

Type NIBE F1145- 5
Emitted capacity (B 0 / W 35) * 4,83 kW
Emitted capacity (B 0 / W 50) ** 3,85 kW
COP (B 0 /W 35) * 4,44
COP (B 0 / W 50) ** 3,13
Height 1500 mm
Width 600 mm
Depth 620 mm
Net weight 148 kg
Operating voltage 230 V (1-phase)
Refrigerant R407C

* In accordance with EN 255 for heat source entry at 0° C / hot water flow at 35° C. The electric input for the circulation pumps is not included. 
** In accordance with EN 255 for heat source entry at 0° C / hot water flow at 50° C. The electric input for the circulation pumps is not included.

Type NIBE F1145- 8 12
Emitted capacity (B 0 / W 35) * 8,33 kW 11,88 kW
Emitted capacity (B 0 / W 50) ** 7,80 kW 11,25 kW
COP (B 0 / W 35) * 4,82 4,60
COP (B 0 / W 50) ** 3,45 3,36
Height 1500 mm 1500 mm
Width 600 mm 600 mm
Depth 620 mm 620 mm
Net weight 165 kg 178 kg
Operating voltage 230 V (1-phase) 230 V (1-phase)
Refrigerant R407C R407C

* In accordance with EN 255 for heat source entry at 0° C / hot water flow at 35° C. The electric input for the circulation pumps is not included. 
** In accordance with EN 255 for heat source entry at 0° C / hot water flow at 50° C. The electric input for the circulation pumps is not included. 

3 x 400 V

Type NIBE F1145- 6 8
Emitted capacity (B 0 / W 35) * 6,31 kW 8,30 kW
Emitted capacity (B 0 / W 50) ** 5,10 kW 6,94 kW
COP (B 0 / W 35) * 4,93 5,01
COP (B 0 / W 50) ** 3,46 3,54
Height 1500 mm 1500 mm
Width 600 mm 600 mm
Depth 620 mm 620 mm
Net weight 145 kg 165 kg
Operating voltage 400 V (3-phase+Zero) 400 V (3-phase+Zero)
Refrigerant R407C R407C

* In accordance with EN 255 for heat source entry at 0° C / hot water flow at 35° C. The electric input for the circulation pumps is not included. 
** In accordance with EN 255 for heat source entry at 0° C / hot water flow at 50° C. The electric input for the circulation pumps is not included. 

Type NIBE F1145- 10 12
Emitted capacity (B 0 / W 35) * 9,95 kW 11,82 kW
Emitted capacity (B 0 / W 50) ** 8,46 kW 11,15 kW
COP (B 0 /W 35) * 5,03 4,79
COP (B 0 / W 50) ** 3,39 3,39
Height 1500 mm 1500 mm
Width 600 mm 600 mm
Depth 620 mm 620 mm
Net weight 170 kg 178 kg
Operating voltage 400 V (3-phase+Zero) 400 V (3-phase+Zero)
Refrigerant R407C R407C

* In accordance with EN 255 for heat source entry at 0° C / hot water flow at 35° C. The electric input for the circulation pumps is not included. 
** In accordance with EN 255 for heat source entry at 0° C / hot water flow at 50° C. The electric input for the circulation pumps is not included. 

Type NIBE F1145- 15 17
Emitted capacity (B 0 / W 35) * 15,75 kW 17,24 kW
Emitted capacity (B 0 / W 50) ** 15,12 kW 16,41 kW
COP (B 0 / W 35) * 4,81 4,60
COP (B 0 / W 50) ** 3,40 3,40
Height 1500 mm 1500 mm
Width 600 mm 600 mm
Depth 620 mm 620 mm
Net weight 191 kg 199 kg
Operating voltage 400 V (3-phase+Zero) 400 V (3-phase+Zero)
Refrigerant R407C R407C

* In accordance with EN 255 for heat source entry at 0° C / hot water flow at 35° C. The electric input for the circulation pumps is not included.
** In accordance with EN 255 for heat source entry at 0° C / hot water flow at 50° C. The electric input for the circulation pumps is not included. 

Heat Pump in your pocket!

Put full control of your NIBE Heat Pump in your pocket. Turn on the heat on your way home or check the status of your indoor climate from anywhere in the world, the possibilites are endless.

Requirements

Download the mobile app

1. Go to Android market
2. Search for NIBE
3. Download the app

Or scan the QR code shown below with your android phone.
(Requires a scanner software in the phone).

 

 

Other accessories